Correlation between Optic Nerve Sheath Diameter, Rotterdam Computed Tomography Score, and Glasgow Coma Scale in Head Injury
DOI:
https://doi.org/10.21776/ub.jkb.2025.033.04.2Keywords:
CT scan, ONSD, RCTSAbstract
Increased intracranial pressure (ICP) is one of the fatal events resulting from head injury. The gold standard for diagnosing elevated ICP, external ventricular drainage (EVD), is highly invasive, unavailable in the initial assessment, and contraindicated in some patients. Optic nerve sheath diameter (ONSD) has recently emerged as a non-invasive alternative for ICP monitoring. The Rotterdam CT Score (RCTS) assesses basal cisterns, midline shift, epidural mass lesion, and intraventricular hemorrhage (IVH) and/or traumatic subarachnoid hemorrhage (tSAH) on head CT scan. High RCTS is associated with higher mortality. Clinically, it can be assessed from level of consciousness with the Glasgow Coma Scale (GCS). This cross-sectional study aims to analyze the correlation between ONSD, RCTS, and GCS in head injury patients who underwent non-contrast head CT scans at the Radiology Department of Adam Malik Hospital, Medan from May 1, 2022, to April 30, 2023. ONSD and RCTS on initial CT scan were measured by two examiners, and GCS scores were obtained from the medical record. From 42 patients, the mean ONSD was 6.26±0.80mm, the median RCTS was 3 (range: 1 to 6), and the median GCS was 14 (range: 3 to 15). There is a significant strong positive correlation between ONSD and RCTS (r=0.747) and a moderate negative correlation between ONSD and GCS (r=-0.476), with p<0.05. The larger the ONSD on the initial head CT scan, the higher the Rotterdam CT score and the lower the GCS score.
Downloads
References
1. Das SK, Shetty SP, and Sen KK. A Novel Triage Tool: Optic Nerve Sheath Diameter in Traumatic Brain Injury and Its Correlation to Rotterdam Computed Tomography (CT) Scoring. Polish Journal of Radiology. 2017; 82: 240-243.
2. Yamamoto Y, Hori S, Ushida K, et al. Impact of Frailty Risk on Adverse Outcomes after Traumatic Brain Injury: A Historical Cohort Study. Journal of Clinical Medicine. 2022; 11(23): 1-9.
3. Ziaei M, Moodi S, Pourafzali SM, and Abdolrazaghnejad A. Diagnostic Value of the Optic Nerve Sheath in the Diagnosis of Increased Intracranial Pressure in Traumatic Brain Patients. Advanced Biomedical Research. 2023; 12(1): 1-5.
4. Kerscher SR, Schöni D, Hurth H, et al. The Relation of Optic Nerve Sheath Diameter (ONSD) and Intracranial Pressure (ICP) in Pediatric Neurosurgery Practice-Part I: Correlations, Age-Dependency and Cut-Off Values. Child's Nervous System. 2020; 36(1): 99–106.
5. Aletreby W, Alharthy A, Brindley PG, et al. Optic Nerve Sheath Diameter Ultrasound for Raised Intracranial Pressure: A Literature Review and Meta‐Analysis of its Diagnostic Accuracy. Journal of Ultrasound in Medicine. 2022; 41(3): 585–595.
6. Durouchoux A, Liguoro D, Sesay M, Le Petit L, and Jecko V. Subarachnoid Space of the Optic Nerve Sheath and Intracranial Hypertension: A Macroscopic, Light and Electron Microscopic Study. Surgical and Radiologic Anatomy. 2022; 44(5): 759–766.
7. Amirtharaj AD, Lazarus ER, and Alzaabi O. Assessing Validity and Reliability of Glasgow Coma Scale and Full Outline of Unresponsiveness Score: A Systematic Review. International Journal of Health Sciences. 2022; 6(S2): 12293–12306.
8. Elkbuli A, Shaikh S, McKenney K, Shanahan H, McKenney M, and McKenney K. Utility of the Marshall & Rotterdam Classification Scores in Predicting Outcomes in Trauma Patients. The Journal of Surgical Research. 2021; 264: 194–198.
9. Charry JD, Falla JD, Ochoa JD, et al. External Validation of the Rotterdam Computed Tomography Score in the Prediction of Mortality in Severe Traumatic Brain Injury. Journal of Neurosciences in Rural Practice. 2017; 8(1): 23–26.
10. Basak D, Chatterjee S, Attergrim J, et al. Glasgow Coma Scale Compared to Other Trauma Scores in Discriminating In-Hospital Mortality of Traumatic Brain Injury Patients Admitted to Urban Indian Hospitals: A Multicentre Prospective Cohort Study. Injury. 2023; 54(1): 93–99.
11. Çelik K and Demiryurek BE. The Association between Intracranial Pressure and Optic Nerve Sheath Diameter on Patients with Head Trauma. Arquivos de Neuro-Psiquiatria. 2021; 79(10): 879-885.
12. Gautam M, Kafle P, Pathak MR, Devkota G, and Ranabhat N. CT Evaluation of Optic Nerve Sheath Diameter in Traumatic Brain Injury and its Correlation with Rotterdam CT Scoring. Nepalese Journal of Radiology. 2020; 10(16): 26-32.
13. Kayadibi Y, Tekerek N, Yesilbas OS, et al. Correlation between Optic Nerve Sheath Diameter and Rotterdam Computer Tomography Scoring in Pediatric Brain Injury. Ulusal Travma ve Acil Cerrahi Dergisi (Turkish Journal of Trauma & Emergency Surgery). 2020; 26(2): 212- 221.
14. Sahu S and Swain A. Optic Nerve Sheath Diameter: A Novel Way to Monitor the Brain. Journal of Neuroanaesthesiology and Critical Care. 2017; 4(4): 13–18.
15. Yogipranata RM and Sukmani H. Korelasi Diameter Selubung Nervus Optik Dan Marshall CT Score Dengan Skala Koma Glasgow Pada Cedera Kepala. Majalah Kedokteran Neurosains Perhimpunan Dokter Spesialis Saraf Indonesia. 2018; 35(3): 188- 193.
16. Chawla H. Reliability of Glasgow Coma Scale in Traumatic Brain Injury: A Retrospective Analysis. Journal of Indian Academy of Forensic Medicine. 2020; 42(1): 17-19.
Downloads
Published
Issue
Section
License
Copyright (c) 2025 Debora Febrina, Netty Delvrita Lubis, Abdurrahman Mousa Arsyad

This work is licensed under a Creative Commons Attribution 4.0 International License.
Authors who publish with this journal agree to the following terms:
- Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).








